Hour and pulse counter combinations for flush and surface/DIN-rail mounting, for AC or DC, 48 x 48 mm
Here you will find a solid solution for a hour and pulse counter combination. Choose between flush or surface/DIN-rail mounting. The connections can be adjusted for a common or separate AC or DC current supply.
Descriptions and application field:
- This counter combination consists of one hour counter and one pulse counter
- The counter operates with common current supply, that means the pulse counter registers the connecting frequency and the hour counter the total operating time of a machine/equipment, i.e. oil burner
Electromechanical hour counters 920
Mounting type:
Flush mounting
Counting range:
Hour counter: 99999,99 h
Pulse counter: ED 100 %, 9999999
Digits character height:
1,5 x 3,5 mm (with lens)
Voltages:
115, 230 V AC, 50 and 60 Hz
Special voltages (at additional cost):
24 V AC, 50 and 60 Hz
Voltage:
24 V DC
Connections:
Standard: With common current supply
At additional cost: With separate current supply, but with same voltage; That means both counters can be separately triggered, order code: E.g. 920/860 (= only for flush mounting)
At additional cost: With separate current supply, but with same voltage; That means both counters can be separately triggered, order code: E.g. 920/860 (= only for flush mounting)
Voltage tolerance:
±10 %
Current consumption (common current supply):
V AC 3 – 8 mA V DC 7 – 13 mA
Protection class DIN 40050:
Housing: IP 65 (front) Terminal: IP 00
Ambient temperature:
–10 °C to +50 °C
Fixing:
Retaining clip
Approval:
CE
Operation indication:
Yes
Weight:
Approx. 55 g
Electromechanical hour counters 920 A.2
Mounting type:
Surface/DIN-rail mounting
Counting range:
Hour counter: 99999,99 h
Pulse counter: ED 100 %, 9999999
Digits character height:
1,5 x 3,5 mm (with lens)
Voltages:
115, 230 V AC, 50 and 60 Hz
Special voltages (at additional cost):
24 V AC, 50 and 60 Hz
Voltage:
24 V DC
Connections:
Standard: With common current supply
At additional cost: With separate current supply, but with same voltage; That means both counters can be separately triggered, order code: E.g. 920/860
At additional cost: With separate current supply, but with same voltage; That means both counters can be separately triggered, order code: E.g. 920/860
Voltage tolerance:
±10 %
Current consumption (common current supply):
V AC 3 – 8 mA V DC 7 – 13 mA
Protection class DIN 40050:
Housing: IP 65
Terminals: IP 20, at additional cost with
Terminal cover: IP 40
Ambient temperature:
–10 °C to +50 °C
Fixing:
Surface/DIN-rail
Approval:
CE
Operation indication:
Yes
Weight:
Approx. 70 g